Home>Proportional Control Valves>Proportional Solenoid Controlled Pilot Valve Without Position Feedback
Proportional Control Valves - Proportional Solenoid  Controlled Pilot Valve Without Position Feedback
Proportional Control Valves - Proportional Solenoid  Controlled Pilot Valve Without Position Feedback

Proportional Solenoid Controlled Pilot Valve Without Position Feedback

1. Pilot type control two-stage proportional directional valve, without the main spool displacement electrical feedback, the main spool by the spring; 2. Accurate stepless flow regulation (without pressure compensation) and direction control can be realized; 3. Pilot valve with central thread proportional electromagnet, coil can be separately removed; 4. Electromagnet with optional manual emergency operation; 5. Used for bottom plate installation, installation surface according to the unified international standard ISO 4401; 6. The electric control device is external, which can be used interchangeably with similar products in Europe and America;
Product Description

4WRZ

E

16

-C2

-125

A

- 10

- D24

- ET

- K31

-A1

-D3

-V

-**

1

  2

3

 4

 5

 6

 7

8

 9

 10

 11

 12

13

 14

1- Pilot type without displacement electrical feedback
2- electronic control blank: external type amplifier plate; E: Integrated amplifier plate
3- Nominal size 10:10 size; 16:16 size; 25:25 path;
4- Slide column function See slide column function table
5- Nominal flow 
      10 diameter 25:25L/min; 50:50L/min; 80:80L/min
      16 diameter 100:100L/min; 150:150L/min
       25 diameter 220:220L/min; 325:325L/min
6- Throttling groove form
7- Design code
8- Power supply voltage blank: none (for 4WRZ); D24:DC24V(for 4WRZE)
9- electromagnet operation blank: no manual emergency operation; N9: Manual emergency operation with guard
10- Control form blank: internal control and internal leakage; E: external control and internal leakage; T: Internal control leakage; ET: External control leakage
11- Electrical connection 4WRZ Blank: with coil plug (PG11); K4: None
4WRZE blank: with amplifier plug; K31: None
12- Control instruction blank: for 4WRZ; A1: command value ±10V; F1: Instruction 4 to 20Ma
13- blank: no fixed pressure reducing valve; D3: With fixed pressure reducing valve
14- Sealing material blank: nitrile rubber; V: Fluorine rubber
15- More details

16:460

Maximum pressure315        bar
Maximum flow

10:170

16:460

25:870

 L/min
Working mediumIn line with DIN51524 standard mineral oil (HL, HLP), other oil please consult our company   /

Recommended viscosity range

20 to 380mm2/s(30 to 46mm2/s is preferred)   /
Oil contamination degree

Pilot control valve: the highest pollution level according to NAS1638 class 7 or ISO4406 class 18/16/13   
Main valve: The highest pollution level is NAS1638 Class 9 or ISO4406 Class 20/18/15

 /